Gluster Scale Out Storage for Cloud using Computational Storage Drives CSD

  • Scale out storage for private and public clouds 
  • Expand storage capacity by up to 250%
  • Boost read and write performance by up to 200%
  • Halve the cost of storage 

  • $AUD $183,015.00

    *RRP Pricing*

    To View Channel Discounts Please Login

  • Ex Tax: $183,015.00

Gluster Scale Out Storage for Cloud using Computational Storage Drives CSD

Gluster Scale Out Storage for Cloud using Computational Storage Drives CSD  Hyperscalers has developed a storage solution based on Gluster FS and Computational Storage Drives by ScaleFlux. The result: The ability t

Gluster Scale Out Storage for Cloud using Computational Storage Drives CSD 

Hyperscalers has developed a storage solution based on Gluster FS and Computational Storage Drives by ScaleFlux. The result: The ability to expand capacity by 150%, double the read and write performance and halve the cost per TB. 

Gluster provides an open-source platform for scale-out public and private cloud storage. When delivered as part an appliance by Hyperscalers, service providers can realise newfound benefits around capacity, performance and cost based on pre-engineered outcomes that can be delivered quickly and reliably. 

Expanding the Capacity of Drives CSD 

The following command can be used to expand the logical capacity of the drive, i.e., the capacity visible to the operating system. 
1. $ sfx-nvme sfx change-cap <device> --cap=<NUM>|-c=<NUM> 
Example: 
2. $ sudo sfx-nvme sfx change-cap /dev/sfdv0n1 -c 9600 

Expanding the logical capacity requires that the corresponding data compression ratio is achieved. For example, if the data is known to have a compression ratio of approximately 3:1 (i.e., 300G of data is compressed to 100G), then increasing the logical capacity of a 3.2T drive to 6.4T can be considered safe. 

Download the full reference guide in the downloads tab. 

Start Configuring using CSD


                    S5X CSD


                      S5Z CSD


                 S5XQ CSD

Architecture

The system architecture for GlusterFS distributed network filesystem that is deployed using this document is as shown in the Figure 5 Gluster FS system architecture


KVPM Graphical Utility 



Testing the Appliance

The test is conducted to attach the client to the target exposing the ScaleFlux CSD 2000 drives as a logical volume. Sequential read and write tests are performed using the IOMeter tool running on a windows machine pinging the dynamo service running on the Linux target machines

Expanded Drive Logical Volume Test

When the CSD is tested after creating a logical volume with two drives of its actual provisioned capacity, the sequential read speed reached to about 4.2GB/s and sequential write speed reached to about 3.2GB/s.

IO Meter Sequential Read Test



IO Meter Sequential Write Test


Contents Page - Download the Referance Guide in the Downloads Tab 

2 List of Figures 3

3 Introduction 4

Audience and Purpose 4

Documents, Knowledge Base, and Technical Support 4

Digital IP Appliance Design Process 4

Appliance Optimizer Utility AOU 4

Important Considerations 6

BIOS is tuned to “High Performance” power and profile configuration. 6

CPUs are tuned to disable idling state 7

Proper ventilation and standard datacentre operating temperature 7

Native Sector Size 8

Memory requirements 8

Verify Supported Interfaces 9

Infrastructure Setup 9

Qualification Hardware with the CSD 9

Driver Install 10

Determine the Linux System Distribution 10

Determining the Kernel Version 10

Installing Binary Drivers 11

Installing Source Drivers 11

Validation 11

4 Base Product Deployment 13

Preinstallation Requirements 13

Modifying Drive Capacity 13

Logical Volume target for the Gluster File System 14

GlusterFS setup and configuration 16

5 Testing the Appliance 17

Extended Capacity Gluster exposed pool testing 17

6 Additional Setup and Deployment 18

Capacity Monitoring 18

Temperature Monitoring 19

Drive Management 20

Changing the Logical Sector Size 20

Enabling Atomic Writes 20

Data Wipe (Factory Reset) 21

7 Addendum 22

Test Suite on single drive 22

2:1 Compressed Individual drive test 22

2:1 Compressed drive LV test 24

Performance chart 26

Performance Comparison 26

8 Trademarks and Licensing 26

9 References 27


Tags: Gluster, FS, scale, out, storage, Cluster, solution, Aus, Australia